I am getting a Construction Assembly or Window Error, what does this mean?

Typically the error will read something like this:

Error:  Construction assembly ‘CONC. WALL7’ may not be assigned to surfaces with more than one Status, i.e. New, Altered or Existing

A limitation of the CEC CBECC engine is that any assemblies or windows in the Building Tree that have a different Status (ie Existing/New/Altered) may not point to the same Assembly or Fenestration entry in the library.

The solution is to create a unique entry for each case, for example create a wall named (e) CONC. WALL that would be assigned to the surfaces that are existing, create another called (n) CONC. WALL for the new instances.

 

Please log in to rate this.
0 people found this helpful.


Category: 9. Nonresidential Title 24 Performance

← I am getting a Construction Assembly or Window Error, what does this mean?